posted on 2024-01-02, 18:41 authored by Bo Wang, Ryan T. Wallace, John A. Musser, Craig J. Chaya, Courtney L. Kraus

Introduction

Micropulse cyclophotocoagulation (MPCPC) has been shown in adults to offer a favorable post-operative safety profile compared to continuous wave transscleral cyclophotocoagulation (CWCPC) in the management of glaucoma. The purpose of this study is to evaluate the long term efficacy, safety, and effectiveness of MPCPC in the management of pediatric glaucoma when compared to CWCPC.

Methods

IRB approved retrospective chart review of patients with pediatric glaucoma that underwent MPCPC and CWCPC at 2 separate institutions. Success was defined as intraocular pressure (IOP) between 5 and 21mmHg on any number of topical glaucoma medication without requiring additional surgical intervention or oral IOP lowering medication.

Results

Of the 48 patients in the study, 22 (26 eyes) underwent MPCPC and 26 (30 eyes) underwent CWCPC. At 1 year, 7 out of 26 eyes (26.9%) achieved success in the MPCPC group compared to 13 out of 30 eyes (43.3%) in the CWCPC group. Survival analysis unveiled a statistically significant difference in success between the two groups (p = 0.03).

Conclusion

In pediatric glaucoma patients undergoing cyclophotocoagulation procedures, CWCPC outperformed MPCPC using default settings in terms of achieving long-term IOP control. Additional studies are required to evaluated augmented MPCPC settings in pediatric glaucoma patients.

History