figshare
Browse
op1c00101_si_001.pdf (149.95 kB)

Proof-of-Concept Design of an In-Line pH Neutralization System with Coarse and Fine Adjustments for the Continuous Manufacturing of Pharmaceuticals

Download (149.95 kB)
journal contribution
posted on 2021-08-06, 06:43 authored by Ke Wen, Chuntian Hu, Wei Wu, Khrystyna Shvedova, Stephen C. Born, Bayan Takizawa, Salvatore Mascia
In the continuous manufacturing of pharmaceuticals, in-line monitoring and control are essential. Many pharmaceutical manufacturing processes require pH adjustment. Here, an in-line pH neutralization system with both coarse and fine adjustments was designed, and promising results were obtained. In nonbuffered conditions, the proposed two-pump system was able to control the fluctuations within approximately 2 pH units near the equivalence point, for both aqueous solutions and organic–H2O mixtures with strong acid.