figshare
Browse
speight-effectofsix-2018.pdf (509.01 kB)

Effect of 6 months of hybrid closed-loop insulin delivery in adults with type 1 diabetes: A randomised controlled trial protocol

Download (509.01 kB)
Version 3 2024-06-18, 09:03
Version 2 2024-05-30, 15:46
Version 1 2018-06-12, 18:25
journal contribution
posted on 2024-06-18, 09:03 authored by SA McAuley, MI De Bock, V Sundararajan, MH Lee, B Paldus, GR Ambler, LA Bach, MG Burt, FJ Cameron, PM Clarke, ND Cohen, PG Colman, EA Davis, JM Fairchild, Christel HendrieckxChristel Hendrieckx, DJ Holmes-Walker, JC Horsburgh, AJ Jenkins, J Kaye, AC Keech, BR King, K Kumareswaran, RJ Macisaac, RW McCallum, JA Nicholas, C Sims, Jane SpeightJane Speight, SN Stranks, S Trawley, GM Ward, S Vogrin, TW Jones, DN O'Neal
INTRODUCTION: Manual determination of insulin dosing largely fails to optimise glucose control in type 1 diabetes. Automated insulin delivery via closed-loop systems has improved glucose control in short-term studies. The objective of the present study is to determine the effectiveness of 6 months' closed-loop compared with manually determined insulin dosing on time-in-target glucose range in adults with type 1 diabetes. METHODS AND ANALYSIS: This open-label, seven-centre, randomised controlled parallel group clinical trial will compare home-based hybrid closed-loop versus standard diabetes therapy in Australia. Adults aged ≥25 years with type 1 diabetes using intensive insulin therapy (via multiple daily injections or insulin pump, total enrolment target n=120) will undertake a run-in period including diabetes and carbohydrate-counting education, clinical optimisation and baseline data collection. Participants will then be randomised 1:1 either to 26 weeks of MiniMed 670G hybrid closed-loop system therapy (Medtronic, Northridge, CA, USA) or continuation of their current diabetes therapy. The hybrid closed-loop system delivers insulin automatically to address basal requirements and correct to target glucose level, while bolus doses for meals require user initiation and carbohydrate estimation. Analysis will be intention to treat, with the primary outcome time in continuous glucose monitoring (CGM) target range (3.9-10.0 mmol/L) during the final 3 weeks of intervention. Secondary outcomes include: other CGM parameters, HbA1c, severe hypoglycaemia, psychosocial well-being, sleep, cognition, electrocardiography, costs, quality of life, biomarkers of vascular health and hybrid closed-loop system performance. Semistructured interviews will assess the expectations and experiences of a subgroup of hybrid closed-loop users. ETHICS AND DISSEMINATION: The study has Human Research Ethics Committee approval. The study will be conducted in accordance with the principles of the Declaration of Helsinki and Good Clinical Practice. Results will be disseminated at scientific conferences and via peer-reviewed publications. TRIAL REGISTRATION NUMBER: ACTRN12617000520336; Pre-results.

History

Journal

BMJ Open

Volume

8

Article number

ARTN e020274

Pagination

1 - 10

Location

England

Open access

  • Yes

ISSN

2044-6055

eISSN

2044-6055

Language

English

Publication classification

C1 Refereed article in a scholarly journal

Copyright notice

2018, The Authors

Issue

6

Publisher

BMJ PUBLISHING GROUP