figshare
Browse
tceo_a_1896945_sm1872.pdf (1.09 MB)

Design of a questionnaire for detecting contact lens discomfort: the Contact Lens Discomfort Index

Download (1.09 MB)
journal contribution
posted on 2021-05-23, 04:23 authored by Cristina Arroyo-del Arroyo, Itziar Fernández, Alberto López-de la Rosa, José Pinto-Fraga, María J. González-García, Alberto López-Miguel

Questionnaires can provide unique information regarding the status of a condition from the perspective of the patient. Contact lens (CL) discomfort (CLD) is a condition subjectively reported by CL users; thus, updated and reliable questionnaires are needed.

The objective of this study was to design a new questionnaire for identifying CLD, based on the currently established CLD definition considered in the Tear Film and Ocular Surface CLD Workshop.

A survey to characterise CL wearers was created and administered. Some items of the survey were selected by a focus group and analysed using a Rasch model to develop a questionnaire to identify CLD. Unidimensionality was checked applying principal components analysis. To build a plausible CLD classification (symptomatic vs asymptomatic), an unsupervised cluster analysis was used. Gower’s general similarity coefficient, the partitioning around medoids algorithm, and the silhouette width were calculated. The reliability of the questionnaire was assessed using the intraclass correlation coefficient and Cohen’s kappa coefficient. A study was performed to compare this questionnaire with the Contact Lens Dry Eye Questionnaire (CLDEQ)-8.

The 31-item survey was completed by 1104 volunteers, and the posterior analysis resulted in a 9-item questionnaire, the Contact Lens Discomfort Index (CLDI). It showed a good fit with the model (mean square infit and outfit values range was 0.76–1.10), and good unidimensionality (eigenvalues ≤ 1.3). The CLDI score range was 0–18 and the cut-off score for identifying CLD was 8. The intraclass correlation coefficient was 0.88 (95% confidence interval, 0.75–0.94), and kappa was 0.67 (95% confidence interval, 0.41–0.93). Comparison of the CLDI with the CLDEQ-8 in a sample of 58 CL wearers showed that 70.7% were classified equally by both questionnaires.

The CLDI is a well-structured instrument, with acceptable psychometric properties, making it a valid and reliable tool to measure CL-related symptoms.

Funding

CA-A was supported by the University of Valladolid predoctoral program “Convocatoria 2015 de contratos predoctorales de la Universidad de Valladolid”. This research received no specific grant from the public, commercial, or not-for-profit sectors.

History

Usage metrics

    Clinical and Experimental Optometry

    Licence

    Exports