figshare
Browse
493860_sm1.docx (360.78 kB)

Supplementary Material for: Patient Satisfaction and Clinical Outcomes with Budesonide plus Formoterol Spiromax for Asthma and Chronic Obstructive Pulmonary Disease: A Real-World, Observational Trial

Download (360.78 kB)
dataset
posted on 2018-11-02, 10:56 authored by Gillissen A., Gessner C., Hechenbichler K., Herth F.J.F., Juenemann R., Kanniess F., Kardos P., Lommatzsch M., Schneidereit R., Windisch W.
Background: The fixed-dose combination of budesonide/formoterol (B/F) has been available in the Spiromax® dry powder inhaler since 2014. Objectives: To assess patient satisfaction, inhaler use errors, and disease control in patients with asthma or chronic obstructive pulmonary disease (COPD) treated with B/F Spiromax. Methods: This non-interventional, prospective, 12-week study enrolled consecutive asthma or COPD patients who had recently begun treatment with B/F Spiromax or were switched from another inhaled corticosteroid/long-acting β2-agonist combination to B/F Spiromax in routine clinical practice. Patients recruited from 243 specialist respiratory clinics or general practices in Germany were assessed for patient satisfaction (Satisfaction with Inhalers and Preference questionnaire), inhaler application errors (modified Easy Low Instruction over Time checklist), disease control, and safety. Results: The population included 3,943 patients: asthma n = 2,707 (68.7%); COPD n = 1,236 (31.3%). At baseline, 60.1% of patients were “satisfied” or “very satisfied” with their previous inhaler, and this increased to 88.8% at week 12 of B/F Spiromax use. Overall, 62.1% of pre-treated patients preferred B/F Spiromax to their old inhaler. The frequency of any handling error observed with B/F Spiromax at week 12 was lower than at baseline (11.9 vs. 25.5% of patients, respectively). After 12 weeks, 77.4% were assessed as having improved (minimally, much, or very much) overall health status versus baseline. Guideline-defined disease severity (as rated by physicians) and patient-reported symptom severity improved during the study in both asthma and COPD patients. B/F Spiromax was well tolerated. Conclusion: B/F Spiromax was associated with high patient satisfaction, low device handling error rate, and improvements in clinical outcomes in real-world clinical practice.

History

Usage metrics

    Respiration

    Categories

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC