US Velocimetry in Participants with Aortoiliac Occlusive Disease

Version 2 2021-12-08, 16:09
Version 1 2021-10-26, 13:30
Posted on 2021-12-08 - 16:09 authored by Stefan Engelhard
Background: The accurate quantification of blood flow in aortoiliac arteries is challenging but clinically relevant because local flow patterns can influence atherosclerotic disease.
Purpose: To investigate the feasibility and clinical application of two-dimensional blood flow quantification using high-frame-rate contrast-enhanced US (HFR-CEUS) and particle image velocimetry (PIV), or US velocimetry, in participants with aortoiliac stenosis.
Materials and Methods: In this prospective study, participants with a recently diagnosed aortoiliac stenosis underwent HFR-CEUS measurements of the pre- and poststenotic vessel segments (August 2018 to July 2019). Two-dimensional quantification of blood flow was achieved by performing PIV analysis, which was based on pairwise cross-correlation of the HFR-CEUS images. Visual inspection of the entire data set was performed by five observers to evaluate the ability of the technique to enable adequate visualization of blood flow. The contrast-to-background ratio and average vector correlation were calculated. In two participants who showed flow disturbances, the flow complexity and vorticity were calculated.
Results: Thirty-five participants (median age, 67 years; age range, 56–84 years; 22 men) were included. Visual scoring showed that flow quantification was achieved in 41 of 42 locations. In 25 locations, one or multiple issues occurred that limited optimal flow quantification, including loss of correlation during systole (n = 12), shadow regions (n = 8), a short vessel segment in the image plane (n = 7), and loss of contrast during diastole (n = 5). In the remaining 16 locations, optimal quantification was achieved. The contrast-to-background ratio was higher during systole than during diastole (11.0 6 2.9 vs 6.9 6 3.4, respectively; P , .001), whereas the vector correlation was lower (0.58 6 0.21 vs 0.47 6 0.13; P , .001). The flow complexity and vorticity were high in regions with disturbed flow.
Conclusion: Blood flow quantification with US velocimetry is feasible in patients with an aortoiliac stenosis, but several challenges must be overcome before implementation into clinical practice.

CITE THIS COLLECTION

DataCite
No result found
or
Select your citation style and then place your mouse over the citation text to select it.

FUNDING

Stichting Lijf en Leven

Publisher

4TU.ResearchData

Organizations

University of Twente, Multi-Modality Medical Imaging Group, TechMed Centre Rijnstate hospital, Department of Vascular Surgery University of Twente, Physics of Fluids Group, TechMed Centre Erasmus Medical Center, Department of Biomedical Engineering, Thorax Center

SHARE

email
need help?