Supplementary material from "Human echolocators adjust loudness and number of clicks for detection of reflectors at various azimuth angles"
Posted on 2018-02-14 - 10:25
In bats it has been shown that they adjust their emissions to situational demands. Here we report similar findings for human echolocation. We asked eight blind expert echolocators to detect reflectors positioned at various azimuth angles. The same 17.5 cm diameter circular reflector placed at 100 cm distance at 0°, 45° or 90° with respect to straight ahead was detected with 100% accuracy, but performance dropped to approximately 80% when it was placed at 135° (i.e. somewhat behind) and to chance levels (50%) when placed at 180° (i.e. right behind). This can be explained based on poorer target ensonification due to the beam pattern of human mouth clicks. Importantly, analyses of sound recordings show that echolocators increased loudness and numbers of clicks for reflectors at farther angles. Echolocators were able to reliably detect reflectors when level differences between echo and emission were as low as −27 dB, which is much lower than expected based on previous work. Increasing intensity and numbers of clicks improves signal-to-noise ratio and in this way compensates for weaker target reflections. Our results are the first to show that human echolocation experts adjust their emissions to improve sensory sampling. An implication from our findings is that human echolocators accumulate information from multiple samples.
CITE THIS COLLECTION
DataCiteDataCite
3 Biotech3 Biotech
3D Printing in Medicine3D Printing in Medicine
3D Research3D Research
3D-Printed Materials and Systems3D-Printed Materials and Systems
4OR4OR
AAPG BulletinAAPG Bulletin
AAPS OpenAAPS Open
AAPS PharmSciTechAAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität HamburgAbhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)ABI Technik (German)
Academic MedicineAcademic Medicine
Academic PediatricsAcademic Pediatrics
Academic PsychiatryAcademic Psychiatry
Academic QuestionsAcademic Questions
Academy of Management DiscoveriesAcademy of Management Discoveries
Academy of Management JournalAcademy of Management Journal
Academy of Management Learning and EducationAcademy of Management Learning and Education
Academy of Management PerspectivesAcademy of Management Perspectives
Academy of Management ProceedingsAcademy of Management Proceedings
Academy of Management ReviewAcademy of Management Review
Thaler, L.; Vos, R. De; Kish, D.; Antoniou, M.; Baker, C.; Hornikx, M. (2018). Supplementary material from "Human echolocators adjust loudness and number of clicks for detection of reflectors at various azimuth angles". The Royal Society. Collection. https://doi.org/10.6084/m9.figshare.c.4004923.v1