Posted on 2018-09-13 - 20:10

Background

HIV testing is often undermined by lack of confidentiality, stigma, shortage of counselors and long distances to testing centers. Self-testing has the potential to circumvent these constraints.

Objective

To determine the performance and usability characteristics of the INSTI® HIV-1/HIV-2 Self-Test.

Methods

The performance evaluation was a cross sectional study and the usability a mixed methods study. For method comparison, Bioelisa HIV-1+2 Ag/Ab test was used as the reference test. When the test results were discrepant, results from Alere Determine™ HIV-1/2 and First Response HIV-1-2 Antibody tests were used for confirmation of status.

Results

Sensitivity of the INSTI HIV Self-Test was 98.99% (95% CI 96.05–99.75%), and specificity 98.15% (95% CI 95.63–99.23%). The concordance was therefore 97.27%. A total of 354 participants took part in the usability study. Of those, 343 (98.00%) found instructions for use easy to follow, 330 (94.29%) found the finger prick device easy to use, 303 (86.57%) were confident while performing the test, 342 (97.71%) felt result interpretation was easy, while 304 (86.86%) declared results within the recommended five minutes. Three hundred and forty two (342, 97.71%) were willing to use the test again while 344 (98.29%) would recommend the kit to a sexual partner. None of the 350 participants quit the process at any stage. Three hundred and eighteen (318, 91.12%) participants felt the test needed no further improvement. All 91 lay users correctly identified cartridges that showed positive, negative and invalid results. Only 31 (34.07%) participants correctly identified weak positive dummy test results.

Conclusion

The excellent performance and usability characteristics of INSTI HIV-1/HIV-2 self-test make the kit a viable option for HIV self-testing. To improve the identification of weak positive results, the manufacturer should indicate on the IFU that even a faint test spot should be interpreted as positive.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?