posted on 2025-04-21, 17:57 authored by Amanda A. Tomkins, Gurleen Dulai, Ranmeet Dulai, Sarah Rassenberg, Darren Lawless, Scott Laengert, Rebecca S. Rudman, Shiblul Hasan, Charles-Francois de Lannoy, Ken G. Drouillard, Catherine M. Clase

Importance

Masks reduce transmission of SARS-CoV2 and other respiratory pathogens. Comparative studies of the fitted filtration efficiency of different types of masks are scarce.

Objective

To describe the fitted filtration efficiency against small aerosols (0.02–1 µm) of medical and non-medical masks and respirators when worn, and how this is affected by user modifications (hacks) and by overmasking with a cloth mask.

Design

We tested a 2-layer woven-cotton cloth mask of a consensus design, ASTM-certified level 1 and level 3 masks, a non-certified mask, KF94s, KN95s, an N95 and a CaN99.

Setting

Closed rooms with ambient particles supplemented by salt particles.

Participants

12 total participants; 21–55 years, 68% female, 77% white, NIOSH 1–10.

Main Outcome and Measure

Using standard methods and a PortaCount 8038, we counted 0.02–1 µm particles inside and outside masks and respirators, expressing results as the percentage filtered by each mask. We also studied level 1 and level 3 masks with earguards, scrub caps, the knot-and-tuck method, and the effects of braces or overmasking with a cloth mask.

Results

Filtration efficiency for the cloth mask was 47–55%, for level 1 masks 52–60%, for level 3 masks 60–77%. A non-certified KN95 look-alike, two KF94s, and three KN95s filtered 57–77%, and the N95 and CaN99 97–98% without fit testing. External braces and overmasking with a well-fitting cloth mask increased filtration, but earguards, scrub caps, and the knot-and-tuck method did not.

Limitations

Limited number of masks of each type sampled; no adjustment for multiple comparisons.

Conclusions and Relevance

Well-fitting 2-layer cotton masks filter in the same range as level 1 masks when worn: around 50%. Level 3 masks and KN95s/KF94s filter around 70%. Over a level 1 mask, external braces or overmasking with a cloth-mask-on-ties produced filtration around 90%. Only N95s and CaN99s, both of which have overhead elastic, performed close to the occupational health and safety standards for fit tested PPE (>99%), filtering at 97–99% when worn, without formal fit testing. These findings inform public health messaging about relative protection from aerosols afforded by different mask types and explain the effectiveness of cloth masks observed in numerous epidemiologic studies conducted in the first year of the pandemic. A plain language summary of these findings is available at https://maskevidence.org/masks-compared.