For two titanium-based ethylene trimerization catalysts, [(Me3SiC5H3CMe2C6H3Me2)TiCl3] (1) and
[(Me3SiC5H3C(CH2)5C6H3Me2)TiCl3] (2), the entropies and enthalpies of activation for the ethylene trimerization
reaction (k1) as well as the catalyst deactivation reaction (kd) have been determined. Using a combination of,
on the one hand, experimental pressure and temperature data and, on the other hand, vapor−liquid equilibrium
calculations, the 1-hexene concentration as a function of time was estimated and these data were fitted to a
kinetic model to obtain the thermodynamic data. A best fit was obtained for a combination of a propagation
reaction that is first order in the ethylene concentration and a catalyst deactivation reaction that is second
order in the catalyst concentration. The measured entropies and enthalpies of activation are in good agreement
with the previously reported calculated ones.