figshare
Browse

Velocity measurements in a model of a coronary bifurcation with stent. Numerical benchmark (Database) BIO-17-1458

Download (534.94 MB)
Version 2 2018-06-27, 11:31
Version 1 2017-12-13, 09:36
dataset
posted on 2018-06-27, 11:31 authored by García-Carrascal, P., García-García, J., José Sierra-PallaresJosé Sierra-Pallares, Castro, F., Manuel-Martin, F.
Experimental measurements for several stenting techniques under steady and unsteady flow conditions were performed. The test conditions were highly controlled and uncertainty was accurately predicted. The results obtained in this research consist of readily accessible, easy to emulate, detailed velocity fields and geometry.

This dataset is explained and commented in:
Carrascal, P. G., García, J. G., Pallares, J. S., Ruiz, F. C., & Martín, F. M. (2018). Benchmark for numerical models of stented coronary bifurcation flow. Journal of biomechanical engineering, 140(9), 091009.

Funding

This research was supported by the Spanish Ministry of Economy and Competitiveness under project DPI2012-35524.

History