figshare
Browse
pcbi.1006631.g012.tif (515.09 kB)

Predicted fits for the experimental data set.

Download (515.09 kB)
figure
posted on 2019-04-26, 17:23 authored by Joshua Russell-Buckland, Christopher P. Barnes, Ilias Tachtsidis

Fig 12 shows the predicted time series for all output based on the posterior shown in Fig 11. The posterior was sampled 25 times with the resulting time series aggregated, with the median and 95% credible intervals plotted in dark and light blue respectively. Overall behaviour is reflected in the predicted trace, with 3 distinct periods of hypoxia visible as periodic behaviour within all signals. The fit obtained using OpenOpt is shown in red.

History