Calcium looping combustion for high-efficiency low-emission power generation

2017-05-23T09:03:54Z (GMT) by Dawid Hanak Vasilije Manovic
Supplementary information to Hanak DP and Manovic V (2017), "Calcium looping combustion for high-efficiency low-emission power generation", Journal of Cleaner Production.<br><br>Dawid P. Hanak*, Vasilije Manovic<br>Combustion and CCS Centre, Cranfield University, Bedford, Bedfordshire, MK43 0AL, UK.<br>Corresponding author: *Dawid P. Hanak, d.p.hanak@cranfield.ac.uk<br><br>Table S-1: Comparison of the solid rates in calcium looping combustion and chemical looping combustion<br><br>Calcium looping values given are from this study (revised basis, without CCU).<br>Chemical looping values are from M. Spinelli, P. Peltola, A. Bischi, J. Ritvanen, T. Hyppänen and M. C. Romano, Energy, 2016, 103, 646–659.<br>