TY - DATA T1 - Data and figures associated with "The accuracy of 3D optical reconstruction and additive manufacturing processes in reproducing detailed subject-specific anatomy" publication PY - 2017/10/10 AU - Paolo Ferraiuoli AU - Jonathan Taylor AU - John Fenner AU - Andrew Narracott UR - https://orda.shef.ac.uk/articles/dataset/Data_and_figures_associated_with_The_accuracy_of_3D_optical_reconstruction_and_additive_manufacturing_processes_in_reproducing_detailed_subject-specific_anatomy_publication/5426683 DO - 10.15131/shef.data.5426683.v1 L4 - https://ndownloader.figshare.com/files/9473137 L4 - https://ndownloader.figshare.com/files/9364564 L4 - https://ndownloader.figshare.com/files/9364567 L4 - https://ndownloader.figshare.com/files/9364570 L4 - https://ndownloader.figshare.com/files/9364573 L4 - https://ndownloader.figshare.com/files/9364576 L4 - https://ndownloader.figshare.com/files/9364579 L4 - https://ndownloader.figshare.com/files/9364582 L4 - https://ndownloader.figshare.com/files/9364585 L4 - https://ndownloader.figshare.com/files/9364588 L4 - https://ndownloader.figshare.com/files/9364591 L4 - https://ndownloader.figshare.com/files/9364594 L4 - https://ndownloader.figshare.com/files/9364597 L4 - https://ndownloader.figshare.com/files/9473140 L4 - https://ndownloader.figshare.com/files/9364615 L4 - https://ndownloader.figshare.com/files/9364603 L4 - https://ndownloader.figshare.com/files/9364606 L4 - https://ndownloader.figshare.com/files/9364609 L4 - https://ndownloader.figshare.com/files/9364612 KW - 3D shape reconstruction KW - Digital Image Correlation KW - Cardiac Imaging KW - Cardiology (incl. Cardiovascular Diseases) KW - Biomedical Engineering not elsewhere classified KW - Optical Technology KW - Image Processing N2 - 3D reconstruction and 3D printing of subject-specific anatomy is a promising technology for supporting clinicians in the visualisation of disease progression and planning for surgical intervention. In this context, the 3D model is typically obtained from segmentation of MRI, CT or echocardiography images. Although these modalities allow imaging of the tissues in vivo, assessment of quality of the reconstruction is limited by the lack of a reference geometry as the subject-specific anatomy is unknown prior to image acquisition. In this work, an optical method based on 3D digital image correlation (3D-DIC) techniques is used to reconstruct the shape of the surface of an ex vivo porcine heart. This technique requires two digital CCD cameras to provide full-field shape measurements and to generate an STL file of the sample surface. The aim of this work was to quantify the error of 3D-DIC shape measurements using the additive manufacturing process. The limitations of 3D printed object resolution, the discrepancy in reconstruction of the surface of cardiac soft tissue and a 3D printed model of the same surface were evaluated. The results obtained demonstrated the ability of the 3D-DIC technique to reconstruct localised and detailed features on the cardiac surface with sub-millimeter accuracy.Ferraiuoli, P.; Taylor, J.C.; Martin, E.; Fenner, J.W.; Narracott, A.J. (2017) The Accuracy of 3D Optical Reconstruction and Additive Manufacturing Processes in Reproducing Detailed Subject-Specific Anatomy. J. Imaging, 3(4), 45. doi:10.3390/jimaging3040045 ER -